Research Article
Deformation Characterisation and Distress Diagnosis of a Metro Shield Tunnel by Adjacent Constructions
| | Working conditions | Maximum deformation (mm) | Flattening rate (2 × max)/(d + max) |
| Normal earth pressure | No reduction in bolt stiffness | 2.4 | 0.8% | No lateral soil pressure, no reduction in bolt stiffness | 6.1 | 2.3% | 10% reduction in bolt stiffness | 2.7 | 1.0% | No reduction in bolt stiffness, 100 mm cracking depth on segments | 7.1 | 2.7% | No reduction in bolt stiffness, 200 mm cracking depth on segments | 8.8 | 3.2% |
| Earth pressure with 10% reduction | No reduction in bolt stiffness | 10 | 3.4% | 10% reduction in bolt stiffness | 46 | 16.9% | 10% reduction in bolt stiffness, 100 mm cracking depth on segments | 54 | 19.8% | 10% reduction in bolt stiffness, 200 mm cracking depth on segments | 69 | 25.2% |
|
|