Roof subsidence with different bolt lengths.

Dynamic time (s)Roof subsidence (mm)
L = 1800 mmL = 2000 mmL = 2200 mmL = 2400 mm

T = 0.00 s56.7356.2757.8357.65
T = 0.02 s56.6856.3457.8757.65
T = 0.04 s65.4267.8167.0966.34
T = 0.06 s77.8277.2275.6474.06
T = 0.08 s111.53110.70108.72106.30