Research Article

Numerical Investigation on the Influence of In-Plane Damage on the Out-of-Plane Behavior of Masonry Infill Walls

Table 5

The information and analysis results of infill walls with different slenderness ratios.

Slenderness ratio (H/T)172634

Thickness (mm)966358
IP-IDR (%)00.30.700.30.700.30.7
Stiffness (kN/mm × 103)3.331.780.941.790.550.271.230.310.15