Research Article
Experimental Study on Bond Performance and Damage Detection of Corroded Reinforced Concrete Specimens
Table 3
The measuring results of experimental specimens.
| Specimen | Pu (kN) | τu (MPa) | Slip |
| C0-35-0 | 116 | 9.31 | 9.17 | C0-35-150 | 123 | 9.79 | 9.61 | C0-35-100 | 126 | 10.03 | 11.58 | C0-45-0 | 124 | 9.87 | 9.65 | C0-45-150 | 126 | 10.03 | 11.29 | C0-45-100 | 135 | 10.75 | 12.37 | C0-55-0 | 152 | 12.10 | 13.65 | C0-55-150 | 155 | 12.34 | 14.05 | C0-55-100 | 160 | 12.74 | 18.19 | C7-35-0 | 107 | 8.52 | 6.79 | C7-35-150 | 109 | 8.68 | 8.21 | C7-35-100 | 115 | 9.16 | 8.93 | C7-45-0 | 121 | 9.63 | 7.62 | C7-45-150 | 124 | 9.87 | 9.00 | C7-45-100 | 127 | 10.11 | 10.21 | C7-55-0 | 127 | 10.11 | 9.37 | C7-55-150 | 138 | 10.99 | 11.08 | C7-55-100 | 148 | 11.78 | 14.82 | C15-35-0 | 95 | 7.56 | 6.44 | C15-35-150 | 99 | 7.88 | 7.07 | C15-35-100 | 100 | 7.96 | 8.28 | C15-45-0 | 100 | 7.96 | 7.27 | C15-45-150 | 107 | 8.52 | 7.96 | C15-45-100 | 114 | 9.08 | 9.86 | C15-55-0 | 124 | 9.87 | 8.17 | C15-55-150 | 128 | 10.19 | 10.45 | C15-55-100 | 141 | 11.23 | 13.80 |
|
|