Research Article

Dynamic Behavior and Serviceability Analysis of a New Type of U-Shaped Steel-Concrete Composite Floor Slab

Table 4

The peak accelerations of the measured points under the eight test conditions.

Measuring point891415162227

(a)
1.7 Hz1.370.980.590.850.890.650.42
2.1 Hz1.781.300.921.321.270.840.73
2.4 Hz2.672.741.063.121.762.140.81

(b)
1.7 Hz1.441.020.781.121.150.810.53
2.1 Hz2.391.571.961.441.420.910.78
2.4 Hz3.412.821.213.731.962.251.26

(c)
1.7 Hz1.971.400.560.621.511.070.60
2.1 Hz3.103.350.740.872.202.381.91
2.4 Hz4.464.035.026.265.544.092.55

(d)
1.7 Hz2.772.311.992.752.391.621.89
2.1 Hz8.398.185.047.358.647.476.05
2.4 Hz10.659.8710.6814.2712.336.993.95

(e)
1.7 Hz2.342.221.772.442.241.100.63
2.1 Hz3.113.443.174.395.091.411.02
2.4 Hz6.806.476.747.496.486.344.97

(f)
1.7 Hz12.1713.0612.6712.2212.3911.8711.32
2.1 Hz13.5713.6313.0114.0914.0012.7211.48
2.4 Hz17.4020.4618.4622.4221.3820.7613.91

(g)
1.7 Hz18.0120.8420.2321.5620.9121.0012.69
2.1 Hz20.1221.8321.2423.0221.8122.0814.83
2.4 Hz21.4525.8923.5428.2327.6127.4218.66

(h)
1.7 Hz1.611.230.821.451.241.060.75
2.1 Hz2.672.762.723.353.443.282.39
2.4 Hz6.956.027.069.647.787.645.19