Research Article
Shear Strength Prediction for SFRC Shear Wall with CFST Columns by Softened Strut and Tie Model
Table 2
Summary of specimen information.
| Identification number | ρsf (%) | Columns fc (MPa) | Columns ft (MPa) | Web fc (MPa) | Web fft (MPa) | Vjh,test (kN) |
| SS-1.0-00-C60 | 0 | 55.9 | 2.76 | 56.3 | 2.81 | 902 | SS-1.0-05-CF60 | 0.5 | 55.5 | 2.73 | 55.2 | 3.67 | 948 | SS-1.0-10-CF60 | 1.0 | 55.5 | 2.74 | 55.1 | 6.15 | 1005 | SS-1.0-15-CF60 | 1.5 | 56.0 | 2.77 | 56.5 | 7.88 | 1048 | SS-1.0-10-CF40 | 1.0 | 38.1 | 2.15 | 38.3 | 3.78 | 810 | SS-1.0-10-CF80 | 1.0 | 64.6 | 3.96 | 65.6 | 6.84 | 1107 |
|
|