Research Article

Failure Analysis of Locally Damaged Slender Steel Bars Strengthened with CFRP Composites: Experiments, Theory, and Computational Simulations

Table 2

Damage and reinforcement of steel specimens in Group 2.

Specimen #Geometry and damage area (cross section size 14 mm × 12 mm/slenderness ratio 144.34)Grinding depth td (mm)Reinforcement areaPaste thickness tn (layer)

JW000-21Lossless steel bar0Unreinforced0
JS000-22
Unit: mm
0.5Unreinforced0
JS142-230.5Damaged area2
JS142-240.6Damaged area2
JS142-250.7Damaged area2
JS152-260.5Whole bar2
JS152-270.6Whole bar2
JS152-280.7Whole bar2