Thermal properties of building materials.
| Building members | Materials | δ (m) | λ (W/mK) | c (J/kgK) | ρ (kg/m3) |
| Bamboo steel composite wall (wall1) | Cement mortar | 0.015 | 0.93 | 1050 | 1800 | Polystyrene board | 0.02 | 0.042 | 1500 | 20 | Bamboo plywood | 0.01 | 0.17 | 2510 | 600 | C-type steel | 0.001 | 58.2 | 480 | 7800 | Mineral wool | 0.098 | 0.05 | 840 | 32 | C-type steel | 0.001 | 58.2 | 480 | 7800 | Bamboo plywood | 0.01 | 0.17 | 2510 | 600 | Cement mortar | 0.015 | 0.93 | 1050 | 1800 |
| Reinforced concrete wall (wall2) | Cement mortar | 0.015 | 0.93 | 1050 | 1800 | Polystyrene board | 0.02 | 0.042 | 1500 | 20 | Reinforced concrete | 0.24 | 1.74 | 1094 | 1700 | Cement mortar | 0.015 | 0.93 | 1050 | 1800 |
| Roof1 for building with wall1 | Fine aggregate concrete | 0.03 | 1.51 | 920 | 2400 | Polystyrene board | 0.02 | 0.042 | 1500 | 20 | Bamboo plywood | 0.01 | 0.17 | 2510 | 600 | C-type steel | 0.001 | 58.2 | 480 | 7800 | Mineral wool | 0.098 | 0.05 | 840 | 32 | C-type steel | 0.001 | 58.2 | 480 | 7800 | Bamboo plywood | 0.01 | 0.17 | 2510 | 600 | Cement mortar | 0.03 | 0.93 | 1050 | 1800 |
| Roof2 for buildings with wall2 | Fine aggregate concrete | 0.03 | 1.51 | 920 | 2400 | Polystyrene board | 0.02 | 0.042 | 1500 | 20 | Reinforced concrete | 0.12 | 1.74 | 920 | 2500 | Cement mortar | 0.03 | 0.93 | 1050 | 1800 |
| Floor | Cement mortar | 0.03 | 0.93 | 1050 | 1800 | Reinforced concrete | 0.12 | 1.74 | 920 | 2500 |
|
|