Research Article
Research on Key Technologies of Floor Heave Control in Soft Rock Roadway
Table 2
Rock strata properties used in numerical modeling.
| Lithology | M (m) | Ρ (kg/m3) | E (GPa) | | K (GPa) | G (GPa) | t (MPa) | c (MPa) | Φ (°) |
| Mudstone | 4.4 | 2550 | 0.68476 | 0.2 | 0.380 | 0.285 | 0.062 | 0.773 | 14.89 | Siltstone | 5.6 | 2540 | 0.90151 | 0.22 | 0.537 | 0.369 | 0.0235 | 1.335 | 22.29 | Mudstone | 1.4 | 2550 | 1.56048 | 0.2 | 0.867 | 0.650 | 0.1557 | 1.109 | 19.87 | No. 4 coal | 1.1 | 1400 | 2.88938 | 0.25 | 1.926 | 1.156 | 0.1648 | 1.36 | 26.87 | Carbonaceous mudstone | 16 | 2550 | 2.50571 | 0.23 | 1.547 | 1.019 | 0.2249 | 1.244 | 23.06 | Siltstone | 2.2 | 2540 | 2.93616 | 0.22 | 1.748 | 1.203 | 0.0604 | 1.72 | 27.58 | Mudstone | 4.6 | 2550 | 3.2031 | 0.2 | 1.780 | 1.335 | 0.2529 | 1.301 | 22.49 | Siltstone | 0.6 | 2540 | 5.49104 | 0.22 | 3.268 | 2.250 | 0.1285 | 2.028 | 30.5 | No. 1 coal | 3.2 | 1400 | 2.44968 | 0.25 | 1.633 | 0.980 | 0.1681 | 1.407 | 27.67 | Oolitic clay rock | 9.3 | 2550 | 1.95694 | 0.2 | 1.087 | 0.815 | 0.1384 | 1.201 | 21.77 | Limestone | 20 | 2100 | 4.03721 | 0.29 | 3.204 | 1.565 | 0.1133 | 3.224 | 27.58 |
|
|