Research Article

Model Experimental Study of Carbon Fiber Heating Wire for Deicing and Snow Melting on a Bridge Deck

Table 7

Temperature change rate of the first layer’s measurement points Nos. 4, 5, and 6 of the ice melting experiment.

Environmental conditions (°C)Initial average temperature (°C)Average temperature at 250 min (°C)Temperature change rate (°C/h)

−2−0.465.41.406
−4−0.814.771.339
−8−1.124.3171.305