Tab 7
/
Research Article
Model Experimental Study of Carbon Fiber Heating Wire for Deicing and Snow Melting on a Bridge Deck
Table 7
Temperature change rate of the first layer’s measurement points Nos. 4, 5, and 6 of the ice melting experiment.
Environmental conditions (°C)
Initial average temperature (°C)
Average temperature at 250 min (°C)
Temperature change rate (°C/h)
−2
−0.46
5.4
1.406
−4
−0.81
4.77
1.339
−8
−1.12
4.317
1.305