Model Experimental Study of Carbon Fiber Heating Wire for Deicing and Snow Melting on a Bridge Deck
Table 8
Temperature change rate of the first layer’s measurement points Nos. 7, 8, and 9 of the ice melting experiment.
Environmental conditions (°C)
Initial average temperature (°C)
Average temperature when rising for 250 min (°C)
Temperature change rate (°C/h)
−2
−0.78
0.41
0.286
−4
−1.23
0.36
0.382
−8
−1.37
0.33
0.408