Orthogonal experimentation test results.

No.SBS (A)Bioasphalt (B)NO (C)Test results
Ductility (cm)Brookfield viscosity (Pa·s)

13% (1)25% (1)6% (1)50.30.486
23% (1)30% (2)8% (2)50.80.431
33% (1)35% (3)10% (3)50.60.395
44% (2)25% (1)8% (2)57.10.657
54% (2)30% (2)10% (3)59.60.433
64% (2)35% (3)6% (1)55.20.643
75% (3)25% (1)10% (3)51.40.825
85% (3)30% (2)6% (1)50.60.842
95% (3)35% (3)8% (2)45.80.886