Research Article
The Innovative Design of Deep In Situ Pressure Retained Coring Based on Magnetic Field Trigger Controller
Table 3
Maximum magnetic force of the valve cover when the valve seat consists of eight identical shape tile magnets in six schemes.
| Distance (mm) | Maximum magnetic force (N) | Scheme 10 | Scheme 11 | Scheme 12 | Scheme 13 | Scheme 14 | Scheme 15 |
| 1 | 264.869 | 328.353 | 175.293 | 182.453 | 199.339 | 286.889 | 5 | 62.423 | 75.978 | 41.999 | 48.249 | 62.507 | 112.262 | 10 | 16.285 | 16.184 | 10.078 | 13.940 | 20.242 | 43.513 | 15 | 6.516 | 3.910 | 3.130 | 5.233 | 7.948 | 18.762 | 20 | 3.384 | 0.957 | 1.228 | 2.339 | 3.278 | 8.315 | 25 | 2.189 | 0.256 | 0.652 | 1.228 | 1.434 | 3.850 | 30 | 1.561 | 0.071 | 0.421 | 0.711 | 0.651 | 1.834 | 35 | 1.168 | 0.020 | 0.301 | 0.447 | 0.300 | 0.867 |
|
|