Research Article

The Innovative Design of Deep In Situ Pressure Retained Coring Based on Magnetic Field Trigger Controller

Table 3

Maximum magnetic force of the valve cover when the valve seat consists of eight identical shape tile magnets in six schemes.

Distance (mm)Maximum magnetic force (N)
Scheme 10Scheme 11Scheme 12Scheme 13Scheme 14Scheme 15

1264.869328.353175.293182.453199.339286.889
562.42375.97841.99948.24962.507112.262
1016.28516.18410.07813.94020.24243.513
156.5163.9103.1305.2337.94818.762
203.3840.9571.2282.3393.2788.315
252.1890.2560.6521.2281.4343.850
301.5610.0710.4210.7110.6511.834
351.1680.0200.3010.4470.3000.867