Research Article

Experimental Study on Fatigue Performance of Negative Bending Moment of Steel-Concrete Continuous Composite Box Girder

Table 5

Cracks of concrete slab of PLG-2 (unit: mm).

PLG-2Before the dynamic loadAfter 200,000 cyclesAfter 400,000 cyclesAfter 600,000 cyclesAfter 800,000 cyclesAfter 1 million cyclesAfter 1.25 million cyclesAfter 1.5 million cycles

Static load (kN)190190190190190190300380
Crack width0.210.230.250.260.270.270.290.32