Research Article

Air Curtain Dust Removal Device Design and Dust Prevention Strategy in Heading Face

Table 3

Average test data.

Test itemUnitDirectionGroup 1Group 2

Exit slit widthmmUpper1220
Right915

Average airflow velocity at the injection outletm/sUpper18.217
Right14.6510.4

Average airflow velocity at a distance of 1 m from the injection outlet (1 m above the base plate)m/sUpper4.64.4
Right3.93.3

Average airflow velocity at a distance of 1.5 m from the injection outlet (1 m above the base plate)m/sUpper2.93.4
Right3.22.78