| Test item | Unit | Direction | Group 1 | Group 2 |
| Exit slit width | mm | Upper | 12 | 20 | Right | 9 | 15 |
| Average airflow velocity at the injection outlet | m/s | Upper | 18.2 | 17 | Right | 14.65 | 10.4 |
| Average airflow velocity at a distance of 1 m from the injection outlet (1 m above the base plate) | m/s | Upper | 4.6 | 4.4 | Right | 3.9 | 3.3 |
| Average airflow velocity at a distance of 1.5 m from the injection outlet (1 m above the base plate) | m/s | Upper | 2.9 | 3.4 | Right | 3.2 | 2.78 |
|
|