Research Article
Mechanical and Dynamic Properties of Hybrid Fiber Reinforced Fly-Ash Concrete
Table 4
Slump and strength test results of HBPC.
| Sample | Concrete slump (mm) | fcu (MPa) | fts (MPa) | fts/fcu |
| 0# | 179 | 20.3 | 1.58 | 0.07798 | 1# | 170 | 24.2 | 1.99 | 0.08211 | 2# | 146 | 24.6 | 2.0 | 0.08121 | 3# | 127 | 26.6 | 2.36 | 0.08866 | 4# | 84 | 25.3 | 2.27 | 0.08992 | 5# | 140 | 25.5 | 2.25 | 0.08832 | 6# | 123 | 25.9 | 2.2 | 0.08476 | 7# | 80 | 25.6 | 2.32 | 0.0908 | 8# | 96 | 27.2 | 2.37 | 0.08713 | 9# | 109 | 24.8 | 2.32 | 0.09356 | 10# | 94 | 25.3 | 2.33 | 0.09218 | 11# | 78 | 29.4 | 2.48 | 0.08425 | 12# | 68 | 29 | 2.54 | 0.08757 | 13# | 75 | 24.6 | 2.37 | 0.09624 | 14# | 44 | 25.7 | 2.43 | 0.09469 | 15# | 35 | 28.8 | 2.59 | 0.08983 | 16# | 26 | 28.2 | 2.48 | 0.08796 |
|
|