Research Article
Deformation and Mechanical Properties of a Constant-Friction-Force Energy-Absorbing Bolt
Table 1
Tensile test results of the EACF bolt.
| Types of EACF bolts | Diameter of the straight section of the damping block (mm) | Straight line length of the damping block (mm) | Average constant-friction force (kN) | Constant displacement (mm) | Absorbed energy (J) |
| BG-1 | 38 | 20 | 60 | 39.4 | 3806 | BG-2 | 38 | 25 | 63 | 39.2 | 4407 | BG-3 | 38 | 30 | 67 | 39.6 | 5215 | BG-4 | 38.5 | 20 | 72 | 39.7 | 4687 | BG-5 | 38.5 | 25 | 75 | 39.7 | 5064 | BG-6 | 38.5 | 30 | 78 | 39.8 | 5746 | BG-7 | 38.7 | 20 | 80 | 39.6 | 5116 | BG-8 | 38.7 | 25 | 83 | 39.8 | 6097 | BG-9 | 38.7 | 30 | 87 | 39.5 | 7340 |
|
|