Optimization of Arabian-Shield-Based Natural Pozzolan and Silica Fume for High-Performance Concrete Using Statistical Design of Experiments
Table 5
Paired t- and two-sample tests for the predicted and observed results.
| Regression method | Variable | Eq. | | Result | Mean (MPa) | Std. Dev. (MPa) | 95% confidence interval of difference | -value | Lower | Upper | Mean | Std. Dev. |
| SLF | Compressive strength | 1a | 0.25 | Observed | 91.71 | 5.25 | −2.08 | 2.08 | 1.000 | 0.238 | Predicted | 91.71 | 4.11 | 1b | 0.40 | Observed | 64.03 | 8.39 | −2.70 | 2.70 | 1.000 | 0.334 | Predicted | 64.03 | 7.23 | Permeability | 2a | 0.25 | Observed | 886.75 | 1148.50 | −78.54 | 71.70 | 0.917 | 0.490 | | | Predicted | 890.38 | 1139.10 | 2b | 0.40 | Observed | 2287.6 | 2669.2 | −126.82 | −126.82 | −126.82 | 0.496 | | | Predicted | 2287.6 | 2667.7 |
| RSD | Compressive strength | 3a | 0.25 | Observed | 91.71 | 5.25 | −2.54 | 2.87 | 0.895 | 0.027 | Predicted | 91.54 | 2.55 | 3b | 0.40 | Observed | 64.03 | 8.39 | −2.81 | 3.14 | 0.905 | 0.287 | Predicted | 63.86 | 6.90 | Permeability | 4a | 0.25 | Observed | 886.75 | 1148.5 | −230.90 | 82.90 | 0.322 | 0.546 | Predicted | 960.75 | 1193.0 | 4b | 0.40 | Observed | 2287.6 | 2669.2 | −230.28 | 224.87 | 0.980 | 0.453 | Predicted | 2290.3 | 2576.7 |
|
|