Research Article

Safety Management System Prototype/Framework of Deep Foundation Pit Based on BIM and IoT

Table 1

Classification of hazardous areas in deep foundation pit construction site.

Type of accidentHazardous area

CollapsePit edge1.2 m from foundation pit edge
Foundation pit supportThe inspection is qualified, and the lack of the latest safety inspection record is regarded as a hazardous area
ScaffoldThe inspection is qualified, and the lack of the latest safety inspection record is regarded as a hazardous area

Falling from a heightManual digging pile hole1 m from the edge of the orifice
The edge of the hole0.6 m from the edge of the hole
Scaffolding formworkCoverage of formwork collapse
Tower crane useThe range of the circle is centred on the hanging object, and the instantaneous reaction distance of the person is the radius

Object strikeSupport erectionThe inspection is qualified, and the lack of the latest safety inspection record is regarded as a hazardous area
ScaffoldingThe inspection is qualified, and the lack of the latest safety inspection record is regarded as a hazardous area
Tower crane usePlane projection area
Tower craneDetecting tower crane speed, with overspeed being considered unsafe area
FormworkDemolishing area

Mechanical injuryCranePlane projection area
Concrete pumpsWork area and moving route
Other moving equipment or machineWork area and moving route

Adjacent environment damageCraneThe maximum range of the circle centred on the hanging object
Support systemRetaining structure or other support element