Research Article

Research on Seismic Test and Calculation Model for Improving Factor of Composite Board with Heat Preservation Function

Table 4

Damping data sheet.

Composite plate typeWall no.heζψ
1△yAvg.2△yAvg.3△yAvg.ζ1ζ2ζ3

Without thermal insulation system10.090.070.090.080.100.091.1431.1251.0001.089
20.070.080.09
30.060.070.07
With thermal insulation system10.090.080.080.090.090.09
20.090.090.09
30.080.090.09

Notes: he denotes the equivalent viscous damping coefficient; ζ denotes the damping evaluation coefficient; ψ denotes the damping improvement factor.