Research Article

Study on Finite Element Model of the Prefabricated Reinforced Concrete Beam-Column Joints with Grouted Sleeves

Table 3

The characteristic points significance analysis of strain.

Characteristic pointSelected variableSteel bar diameterTotal length of sleeveYield strength of reinforcementSelected variable

Yield strength point ASignificance sig.0.0760.000.2880.901
Value t15.2329.23−1.089−3.811
Yield platform BSignificance sig.0.0640.000.3450.832
Value t10.7326.78−3.066−4.312
Yield strength point CSignificance sig.0.0140.000.3450.832
Value t16.2319.55−4.098−5.152