Failure moment and load results for tested beams.

Case no.SpecimenFailure1 load (KN)Failure moment (kN·m)Failure mode

Group AS-A-117.33.46Delamination2
S-A-220.84.16Delamination2
S-A-3255Delamination2

Group BS-B-124.62.46Delamination3
S-B-226.642.66Compression4 buckling
S-B-3282.8Delamination3
S-B-4292.9Compression4 buckling

1The total failure loads on the beam (cell load) which is equal to 2P. 2Delamination at the web-bottom flange junction. 3Delamination at the web-top flange junction led to the localized buckling of the web. 4The beam failed with a huge compression buckling of top flange.