Research Article
Experimental Study on Anchorage Performance of Resin Grout with Steel Segment
Table 5
Average peak load and energy absorption capacity of each group.
| Adding amount | Addition type | 0.6 mm | 1.2 mm | 2.1 mm | 3.0 mm | Peak load (kN) | Energy absorption (J) | Peak load (kN) | Energy absorption (J) | Peak load (kN) | Energy absorption (J) | Peak load (kN) | Energy absorption (J) |
| 0 | 103.3 | 486.65 | 103.3 | 486.65 | 103.3 | 486.65 | 103.3 | 486.65 | 20 | 106.8 | 532.92 | 110.1 | 580.15 | 116.16 | 609.19 | 118.23 | 590.11 | 30 | 107.4 | 574.66 | 121.78 | 754.74 | 126.1 | 740.25 | 134.0 | 764.06 | 40 | 114.56 | 599.09 | 126.88 | 732.33 | 141.53 | 788.61 | 156.32 | 1,026.88 | 50 | 115.2 | 618.66 | 138.72 | 769.46 | 135.79 | 760.02 | 134.33 | 826.55 | 60 | 111.7 | 566.74 | 87.25 | 371.34 | 111.96 | 676.76 | 97.7 | 448.41 |
|
|