Research Article

Strain Accumulation in Soft Marine Clay due to One-Way Cyclic Load with Variable Confining Pressure

Table 2

Scheme of CCP and VCP tests.

Number of tests0 (kPa)qampl (kPa)CSRηamplNumber of load cycles

D01100150.20833000
D02100150.2081.03000
D03100150.2080.53000
D04100200.27833000
D05100200.2781.03000
D06100200.2780.53000
D07100200.2780.43000
D08100200.2780.33000
D09100250.34733000
D10100250.3471.03000
D11100250.3470.53000
D12100350. 48633000
D13100350.4861.03000
D14100350.4860.53000
D15100350.4860.43000
D16100450.62533000
D17100450.6251.03000
D18100450.6250.53000
D19100550.76433000
D20100600.83333000
D21100650.90333000