Research Article

Study on Deformation Law of Subway Construction under Passing Existing Line in Short Distance

Table 3

Comparison of monitoring results and numerical simulation.

Reinforcement measuresPositionMonitoring (mm)Simulating value (mm)

Ungrouted reinforcementSubgrade structure9.929.89
Track structureAct9.89

Grouting reinforcementSubgrade structure1.811.93
Track structure1.821.93