Push-out test results.

Shear connector typeSpecimensMaximumDuctility factor
(kN) (kN) (mm) (mm)

StudA-1-1430.65446.061.271.312.252.51
A-1-2461.471.362.77
Arc-shaped reinforcementC-1-11290.881168.110.560.612.042.18
C-1-21045.330.652.32
C-2-11569.131475.460.610.643.293.29
C-2-21381.780.683.29
C-3-11746.051801.260.960.866.195.98
C-3-21856.470.755.77
Perforated bar steel plateB-3-1827.03791.792.152.315.586.23
B-3-2755.352.486.88