Research Article
Cement Slurry Plugging Law and Optimal Plugging Flow Rate at a High Hydraulic Gradient
Table 6
Reverse diffusion distances in the 70 mm diameter pipe.
| Factor | Water-cement ratio (W/C) | Hydrodynamic velocity (m·s−1) | Injection pressure (MPa) |
| K1 | 1770 | 2470 | 1510 | K2 | 1900 | 1500 | 1720 | K3 | 1300 | 1030 | 1740 | k1 | 590 | 813 | 503 | k2 | 633 | 500 | 573 | k3 | 433 | 343 | 580 | Range | 157 | 470 | 80 | Primary and secondary factor | Hydrodynamic velocity > water-cement ratio > injection pressure |
|
|