Research Article

Evaluation of the Floor Acceleration Amplification Demand of Instrumented Buildings

Table 6

Velocity factor (α) in the lowrise masonry buildings.

PGA (g)Fitted65%75%85%

≤0.0352.061.842.313.00
0.035–0.11.841.682.512.64
0.1–0.22.822.993.003.00
>0.2NANANANA