Comparison of grouting reinforcement effect in various simulation schemes.
| Scheme number | Average surface settlement (mm) | Average value of void pressure in area II (MPa) | Average section reduction rate (%) | Number of fissures | Maximum value of principal stress difference (MPa) |
| 1 | 56 | 0.79 | 1.66 | 877 | 0.60 | 2 | 51 | 0.77 | 1.45 | 1489 | 0.50 | 3 | -- | 0.75 | 1.61 | 2087 | 0.90 | 4 | 59 | 0.91 | 2.20 | 896 | 0.60 | 5 | 55 | 0.77 | 1.57 | 1396 | 1.00 | 6 | 45 | 0.76 | 1.54 | 2055 | 0.90 | 7 | 55 | 0.77 | 1.57 | 946 | 0.65 | 8 | 50 | 0.75 | 1.56 | 1428 | 0.50 | 9 | -- | 0.74 | 0.80 | 2034 | 0.65 |
|
|