Research Article

Temporal and Spatial Effect of Surrounding Rock and Supporting Construction of a Large Soil Tunnel

Table 1

Initial support design parameters.

NamePositionParameter
Diameter/mmLength/m

Hot rolled seamless steel pipe140° range of arch424.0
Mortar boltSidewall22
Locking catheterArch foot42
Connecting barBetween adjacent archesɸ22
ConcreteInitial spraying5 cm
Second lining arch50 cm
Secondary lining low side wall60 cm
Double lining invert27 cm thickness
Steel archHolocycleType I20