Research Article
Experimental and Numerical Analysis of a High-Rise Structure with a Dual FPS Isolation System
Table 4
Top acceleration vibration reduction rate of the structure FPS isolation system/(%).
| ā | PGA (g) | 1940 El Centro | 1952 Taft | 1979 Imperial Valley | 1994 Northridge |
| FPS base isolation structure | 0.1 | 28.22 | 12.00 | 29.35 | 29.35 | 0.15 | 41.40 | 36.39 | 11.53 | 23.56 | 0.2 | 21.19 | 49.38 | 7.20 | 17.65 | 0.25 | 35.56 | 43.39 | 41.39 | 27.78 | FPS inter-storey isolation structure | 0.1 | 25.81 | 22.37 | 28.74 | 28.74 | 0.15 | 31.64 | 39.10 | 41.85 | 55.41 | 0.2 | 41.27 | 45.99 | 29.55 | 30.99 | 0.25 | 59.14 | 54.83 | 19.59 | 51.86 | FPS dual isolation structure | 0.1 | 51.98 | 42.94 | 38.16 | 38.16 | 0.15 | 54.50 | 56.47 | 55.20 | 41.55 | 0.2 | 49.36 | 64.53 | 50.53 | 54.00 | 0.25 | 61.98 | 57.79 | 52.59 | 61.62 |
|
|