Compression Performance and Calculation Method of Thin-Walled Prefabricated Steel Tube Lightweight Concrete Columns
Table 1
Parameters of the specimens.
| No. | Cross section height (mm) | Component length (mm) | Component thickness (mm) | Concrete strength | Section width-to-thickness ratio | Steel pipe cross-sectional area (mm2) | Steel content | Slenderness ratio |
| Z120-2.2-20 | 120 | 1500 | 2.2 | LC20 | 54.55 | 932 | 15.5% | 30 | Z120-2.2-25 | 120 | 1500 | 2.2 | LC25 | 54.55 | 932 | 15.5% | 30 | Z120-2.2-30 | 120 | 1500 | 2.2 | LC30 | 54.55 | 932 | 15.5% | 30 | Z120-2.2-k | 120 | 1500 | 2.2 | Hollow | 54.55 | 932 | — | 30 | Z120-3.0-20 | 120 | 1500 | 3.0 | LC20 | 40 | 1140 | 19% | 30 | Z120-3.0-25 | 120 | 1500 | 3.0 | LC25 | 40 | 1140 | 19% | 30 | Z120-3.0-30 | 120 | 1500 | 3.0 | LC30 | 40 | 1140 | 19% | 30 | Z120-3.0-k | 120 | 1500 | 3.0 | Hollow | 40 | 114 | — | 30 | Z200-2.2-20 | 200 | 1500 | 2.2 | LC20 | 90.91 | 1188 | 8.5% | 21.4 | Z200-2.2-25 | 200 | 1500 | 2.2 | LC25 | 90.91 | 1188 | 8.5% | 21.4 | Z200-2.2-30 | 200 | 1500 | 2.2 | LC30 | 90.91 | 1188 | 8.5% | 21.4 | Z200-2.2-k | 200 | 1500 | 2.2 | Hollow | 90.91 | 1188 | — | 21.4 | Z200-3.0-20 | 200 | 1500 | 3.0 | LC20 | 66.67 | 1620 | 11.6% | 21.4 | Z200-3.0-25 | 200 | 1500 | 3.0 | LC25 | 66.67 | 1620 | 11.6% | 21.4 | Z200-3.0-30 | 200 | 1500 | 3.0 | LC30 | 66.67 | 1620 | 11.6% | 21.4 | Z200-3.0-k | 200 | 1500 | 3.0 | Hollow | 66.67 | 1620 | — | 21.4 |
|
|