Research Article

Experimental Study on the Effect of Large Temperature Difference on Compressive Strength and Pore Structure of Semirigid Base

Table 1

Semirigid base mineral grading table.

Sieve hole size31.5 mm26.5199.54.752.360.60.075

Quality pass percentage (%)10076.846.429.319.99.42.7
Target grading rangeUpper limit10086853228153
Lower limit1006835221680