Research Article

Experimental Study on the Effect of Large Temperature Difference on Compressive Strength and Pore Structure of Semirigid Base

Table 3

Uniaxial compression experimental results of semirigid base material under the temperature range of 20°C∼60°C.

Number of cyclesParallel strength test value (MPa)Intensity representative value (MPa)Standard deviationCoefficient of variation (%)

010.6112.8214.0612.501.7513.95
317.4316.0615.4216.31.036.3
612.8413.1515.3113.771.359.77
911.7213.2115.6313.521.9714.6
1210.8811.6713.9112.151.5712.93
1511.949.5510.2210.571.2311.66