Review Article

Dynamic Behaviors of Fiber-Reinforced Cellular Concrete Fabricated with Millimeter-Sized Superabsorbent Polymer

Table 4

Quasistatic compressive test results for cellular concrete.

IDfquasi.c (MPa)Equasi (MPa)Rquasi (MJ/m3)

K146.813,061.890.0908
K252.213,153.050.1130
K334.912,003.690.0602
K447.314,028.550.0701
K537.612,856.410.0597
K636.012,229.590.0649
K717.02,944.390.0551
K819.03,085.160.0742
K916.93,014.110.0532
K1015.33,023.570.0521
K1114.92,844.740.0477
K1213.52,668.110.0407