Research Article

Investigations on Incipient Fault Diagnosis of Power Transformer Using Neural Networks and Adaptive Neurofuzzy Inference System

Table 3

Results of diagnosis on transformer oil samples. Total number of DGA samples in database = 563.

NetworksNetwork topology and number of neurons/rulesSamples in training% training accuracySamples in testing% testing accuracy% validation accuracy

RBFNN27522598.7816998.8198.85
BPNN7 × 7 × 122599.5516999.1194.40
ANFIS1 × 7, 1 × 1, 2187 rules22593.83 16992.33