Irene Sales-Pardo, Ariadna Avendaño, Vanessa Martinez-Muñoz, Marta García-Escarp, Raquel Celis, Phil Whittle, Jordi Barquinero, Joan Carles Domingo, Pedro Marin, Jordi Petriz, "Flow Cytometry of the Side Population: Tips & Tricks", Analytical Cellular Pathology, vol. 28, Article ID 536519, 17 pages, 2006. https://doi.org/10.1155/2006/536519

Flow Cytometry of the Side Population: Tips & Tricks

Abstract

Background: The Side Population (SP) has become an important hallmark for the definition of the stem cell compartment, especially in the detection of these cells and in their physical isolation by fluorescence-activated cell sorting (FACS). SP cells are CD34neg and were discovered using ultraviolet excitation based on the efflux of Hoechst 33342 (Ho342). Although the method works as originally described, we believe that this method is difficult for most investigators. First, because the ability to discriminate SP cells is based on the differential retention of Ho342 during a functional assay; second, because of the difficulties in setting the right experimental and acquisition conditions; and third, because the analysis of the acquired data requires an extensive expertise on flow cytometry to accurately detect the SP events. Methods: First of all and mainly for the SP application, the laser beam paths were exhaustively checked to ensure the lowest coefficients of variation. Blood suspensions were prepared by erythrocyte lysis with ammonium chloride and hematopoietic cells were labeled with Ho342. Results: The Ho342 concentration and the staining procedure are critical for the optimal resolution of the SP cells. Although UV laser alignment is very important to resolve the dim tail that outlines the SP, the problem with Ho342 excitation is not the Hoechst Blue emission, but rather the Hoechst Red's (because of the weak emission). Conclusions: Each laboratory must establish its own expected ranges based on its instrument and results may vary slightly due to instrument differences such as the narrowness of the band pass filters, laser power, laser emission wavelength, nozzle type, differential of pressure, light collection system (cuvette versus jet-in-air) and beam shaping optics.

Copyright © 2006 Hindawi Publishing Corporation and the authors. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


More related articles

 PDF Download Citation Citation
 Order printed copiesOrder
Views81
Downloads838
Citations

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.