Research Article

Comparison of Ultrasound-Guided Fine-Needle Cytology Quality in Thyroid Nodules with 22-, 23-, and 25-Gauge Needles

Table 1

Scoring system for specimen quality analysis for thyroid nodules.

Smear parameters and quality descriptionScores

Background of blood or clot
 Excessive: nondiagnosis0
 Intermediate: diagnosis possible1
 Minimal: diagnosed easily2
Number of obtained cells
 Minimal: nondiagnosis0
 Intermediate: diagnosis possible1
 Abundant: diagnosed easily2
Preserved tissue architecture
 Minimal to absent: nondiagnosis0
 Intermediate: some preservation1
 Well preserved: diagnosed easily2
Cellular degeneration
 Severe: nondiagnosis0
 Intermediate: diagnosis possible1
 Minimal: diagnosed easily2

0-≤2 points: unable to diagnose; >2-≤5 points: diagnosable; >5-≤8 points: easy to diagnose.