Research Article
Peak Voltage Measurements Using Standard Sphere Gap Method
Table 1
Breakdown voltage data.
|
Distance [cm] | Test conditions: 19°C; 760.56 mmHg; 8.13 g/m3 | Experimental breakdown voltage [kVmax] | Standard peak values at STC [kVmax] | Theoretical values [kVmax] | Standard peak values [2] [kVmax] |
| 1 |
31.02 | 31.19 | 31.16 | 31.10 | 1.5 | 46.53 | 45.64 | 45.73 | 45.50 | 2 | 59.22 | 59.38 | 59.67 | 59.20 | 2.5 | 71.06 | 73.12 | 73.01 | 72.90 | 3 | 83.24 | 86.06 | 85.77 | 85.80 | 3.5 | 94.97 | 98.70 | 97.98 | 98.40 | 4 | 106.10 | 111.33 | 109.67 | 111 | 4.5 | 119.62 | 123.37 | 120.86 | 123 | 5 | 131.97 | 134.40 | 131.58 | 134 | 5.5 | 140.79 | 145.44 | 141.84 | 145 | 6 | 148.89 | 155.47 | 151.67 | 155 |
|
|