Research Article
Investigation of the Aquifer Protective Capacity and Groundwater Quality around Some Open Dumpsites in Sapele Delta State, Nigeria
Table 3
First-order geoelectric parameter and Dar Zarrouk parameter of the study area.
| S. no. | Protecting layers | Protecting layers resistivity | Thickness | | | Longitudinal conductivity of protecting layers = hT/R | Protective capacity rating |
| VES 1 | 1 | 41.5 | 1.5 | 53.75 | 48.8 | 0.9079 | Good | 2 | 17.1 | 4.4 | 3 | 142.7 | 13.8 | 4 | 13.7 | 29.1 |
| VES 2 | 1 | 18.0 | 1.0 | 36.17 | 15 | 0.4147 | Moderate | 2 | 75.8 | 3.8 | 3 | 14.7 | 10.2 |
| VES 3 | 1 | 26.0 | 1.0 | 184.7 | 40.6 | 0.2198 | Moderate | 2 | 62.5 | 6.0 | 3 | 25.4 | 16.9 | 4 | 70.8 | 16.7 |
| VES 4 | 1 | 65.1 | 1.0 | 57.15 | 7 | 0.1225 | Weak | 2 | 49.2 | 6.0 |
| VES 5 | 1 | 45.6 | 1.0 | 60.6 | 43.2 | 0.7129 | Good | 2 | 78.5 | 7.0 | 3 | 35.0 | 16.2 | 4 | 83.3 | 19.0 |
| VES 6 | 1 | 41.9 | 1.0 | 161.3 | 24.4 | 0.6909 | Moderate | 2 | 81.8 | 7.3 | 3 | 37.6 | 16.1 | 4 | 89.5 | 18.8 |
| VES 7 | 1 | 71.8 | 0.1 | 147.7 | 139.13 | 0.3004 | Moderate | 2 | 235.3 | 5.8 | 3 | 127.1 | 15.6 | 4 | 122.3 | 20.3 |
| VES 8 | 1 | 207.0 | 1.0 | 207 | 1 | 0.0048 | Poor |
| VES 9 | 1 | 312.1 | 1.1 | 312.1 | 1.1 | 0.0035 | Poor |
|
|