Review Article

Current Status and Future Prospects of the SNO+ Experiment

Table 4

Expected background counts in the signal ROI and 3.5 m FV in SNO+ for the first year (year 1) and in 5 years of the 0.3% Te-loading phase. A light yield of 200 Nhits/MeV has been assumed. Cuts have been applied as described in the text.

Isotope1 year5 years

6.331.6
8B    ES7.336.3
Uranium chain2.110.4
Thorium chain1.78.7
External3.618.1
0.10.8
Cosmogenics0.70.8

Total21.8106.8