Figure 2

(a) Comparison of the TEB-RAMS model simulated daily 2 m air temperatures with observations from 01 to 15 July 2003, at the Guanxiangtai station. The black filled circle line represents the observed 2 m air temperature in Beijing, and the black open circle line represents the TEB-RAMS simulated 2 m air temperature. (b) The scatter diagram of correlation relationship between the simulated 2 m air temperature and the observed temperature. The black line represents the linear fit trend.
602528.fig.002a
(a)
602528.fig.002b
(b)