Research Article
Influence of Urban Microclimate on Air-Conditioning Energy Needs and Indoor Thermal Comfort in Houses
Table 6
and
for naturally ventilated living room and bedroom at each site.
| Item | Weather data | Selected sites | A | B | C | D | E | F | G | H | I | J |
| Living room | | Obser. | 391 | 516 | 408 | 326 | 381 | 526 | 464 | 311 | 360 | 432 | Morph. | 420 | 536 | 428 | 365 | 439 | 546 | 497 | 364 | 416 | 435 | Error | 7.4 | 3.9 | 4.9 | 12.0 | 15.2 | 3.8 | 7.1 | 17.0 | 15.6 | 0.7 | | Obser. | 485 | 684 | 512 | 400 | 474 | 698 | 595 | 374 | 447 | 546 | Morph. | 548 | 738 | 562 | 460 | 591 | 765 | 667 | 462 | 545 | 575 | Error | 12.9 | 7.8 | 9.7 | 15.0 | 24.5 | 9.6 | 12.2 | 23.3 | 21.8 | 5.3 |
| Master bedroom | | Obser. | 357 | 625 | 374 | 257 | 311 | 596 | 491 | 205 | 305 | 445 | Morph. | 460 | 680 | 480 | 341 | 508 | 720 | 588 | 334 | 451 | 508 | Error | 28.9 | 8.8 | 28.3 | 32.7 | 63.3 | 20.8 | 19.8 | 62.9 | 47.9 | 14.2 | | Obser. | 417 | 764 | 437 | 296 | 365 | 727 | 582 | 234 | 355 | 524 | Morph. | 556 | 864 | 582 | 403 | 631 | 927 | 733 | 400 | 548 | 617 | Error | 33.4 | 13.1 | 33.2 | 36.3 | 73.0 | 27.4 | 26.0 | 70.5 | 54.4 | 17.6 |
|
|
Unit: in hour; in °C-hour; error in %.
|