Research Article

Evaluating the Effects of Façade Greening on Human Bioclimate in a Complex Urban Environment

Table 2

Overview of the input parameters and model settings in the seven experiments. “X” represents input of times series of meteorological data.

Input parameterNameE0aE0E1R0R1S0S1
ModelENVI-met 3ENVI-met 4RayManSOLWEIG

Meteorological data: initial Unit
Wind speed (10 m)m/s2.32.32.3
Wind direction (10 m)deg57.057.057.0
Potential air temperature (2500 m) °C24.8524.8524.85
Specific humidity (2500 m)g/kg8.568.568.56
Relative humidity (2 m)%45.845.8
Meteorological data
Air temperature (1.1 m) °CXXXXX
Relative humidity (1.1 m)%XXXXX
Global radiationW/m²XX
Soil data
Initial soil temperature (0–50 cm) °C23.10–25.7123.10–25.7123.10–25.71
Relative soil humidity (0–50 cm)%25.0025.0025.00
Environmental parameter
Albedo surroundings0.300.300.360.36
Albedo (wall)0.360.360.36
Albedo (roof)0.200.200.20
Albedo (plant)0.280.280.280.280.28
Transmissivity of vegetation0.280.28
Emissivity (ground)0.950.95
Emissivity (walls)0.900.90
Bowen ratio1.001.00
Solar adjustment factor0.850.850.85