Research Article

Accuracy Improvement of Discharge Measurement with Modification of Distance Made Good Heading

Table 5

Comparison of maximum measured and observed discharge.

CaseFlow conditionMax. measured discharge (m3/s)Max. observed discharge (m3/s)Difference (m3/s)Difference (%)

1Normal126.20127.631.431.12
2Normal126.74127.630.890.70
3Normal124.84127.632.792.19
4Normal122.92127.634.713.69
5Normal129.83127.632.201.72
6Flood1771.132020.62249.4912.35
7Flood1545.011976.32431.3121.82