Comparison of maximum measured and observed discharge.
| Case | Flow condition | Max. measured discharge (m3/s) | Max. observed discharge (m3/s) | Difference (m3/s) | Difference (%) |
| 1 | Normal | 126.20 | 127.63 | 1.43 | 1.12 | 2 | Normal | 126.74 | 127.63 | 0.89 | 0.70 | 3 | Normal | 124.84 | 127.63 | 2.79 | 2.19 | 4 | Normal | 122.92 | 127.63 | 4.71 | 3.69 | 5 | Normal | 129.83 | 127.63 | 2.20 | 1.72 | 6 | Flood | 1771.13 | 2020.62 | 249.49 | 12.35 | 7 | Flood | 1545.01 | 1976.32 | 431.31 | 21.82 |
|
|