Research Article

Improving the Accuracy of Fictitious Domain Method Using Indicator Function from Volume Intersection

Table 3

Comparison of the present computation of drag coefficient () with other results for flow past a cylinder.

PresentGallier et al. [14]Nishioka et al. [21]Rajani et al. [22]Takami et al. [23]
Case1Case2Case3(Numerical)(Experimental)(Numerical)(Numerical)

102.9913.0373.0493.1162.742.8392.754
202.1262.1642.1742.2361.952.0592.003
401.5731.6041.6111.6681.491.5391.536
1001.3021.3211.3281.3761.335
2001.2461.3351.3811.4021.337