Research Article

Multimode Process Monitoring Method Based on Multiblock Projection Nonnegative Matrix Factorization

Table 2

Comparison of fault detection accuracy (%).

Fault no.PCANMFPNMFMPNMF

199.310099.697.499.691.699.991.2
298.39998.496.898.496.098.695.6
36.34.910.48.815.49.121.412.1
431.110077.599.257.799.010011.6
527.826.93336.135.934.336.898.9
699.410010099.910099.6100100
710010097.8100100100100100
897.494.99897.398.697.898.997.1
95.34.67.816.510.315.413.311.3
1045.649.655.457.457.057.863.659.5
1148.180.56968.367.160.978.117.7
1298.594.699.498.399.598.699.5100
1394.395.394.893.894.994.195.094.7
1499.510010099.910091.410087.7
158.58.31910.820.510.923.818.0
163047.643.955.849.054.555.852.4
17809689.395.387.895.491.788.2
1889.990.590.591.490.591.192.290.2
1914.528.810.337.38.439.027.431.0
2042.56055.56757.567.362.881.2
2140.656.14647.546.651.657. 662.1

The significant test results are shown in bold.