Natural frequencies and comparisons.

OWT nameNatural frequency (Hz) and error (%)
Measured frequencyCase 1Case 2Case 3
FrequencyErrorFrequencyErrorFrequencyError

I Lely A20.6340.73816.530.6766.560.72715.34
II Irene Vorrink0.5460.62915.310.5622.870.60310.51
III Blyth0.4880.456−6.610.395−19.030.470−3.60
IV Kentish flats0.3390.3482.600.313−7.750.3390.01
V Barrow0.3690.360−2.410.300−18.560.361−2.08
VI Thanet0.3700.346−6.570.281−23.970.351−5.19
VII Belwind0.3720.3781.610.322−13.490.3781.34
VIII Burbo Bank0.2920.2950.960.2704−7.390.2920.07
IX Walney0.3500.329−6.080.285−18.540.330−5.68
X Gunfleet Sands0.3140.300−4.420.268−14.520.302−3.82
XI ZJU-P0.2620.250−4.350.201−23.200.2661.45