Research Article

Analysis of Magnetohydrodynamic Micropolar Nanofluid Flow due to Radially Stretchable Rotating Disk Employing Spectral Method

Table 3

Confirmation results of for the values of the Biot number with , and values of the rest parameter zero.

[10][51][52]Current upshot

0.050.1446610.1446610.1446610.14466131
0.10.2527580.2527580.2527580.25275796
0.20.4035230.4035230.4035220.40352274
0.40.5750140.5750140.5750130.57501363
0.60.6699150.6699160.6699150.66991582
0.80.7301700.7301700.7301690.73017015
1.00.7718220.7718220.7718220.77182232
5.00.9441740.9441740.9441730.94417371
10.00.9712850.9712850.9712850.97128494